TSL power specifications
Technicial Specifications
Heat dissipation at 10°C |
10,15,25,33 W/m |
Max. Operating temperature |
+65 °C |
Max. allowable no-load temperature |
+85 ° C |
Min mounting temperature |
-55°C |
Min bending radius |
25mm |
rated voltage |
220-240V |
Degree of protection |
IP66 |
temperature class |
T6 |
P version of the shell |
– polyolefin shell recommended for use with weak inorganic solutions |
F shell version |
– fluoropolymer shell recommended for organic corrosive media |
Click to Download Original PDF File!
TECHNOLOGY
The main element of self-regulating cables TSL – heating conductor matrix. Its production is based on the extrusion method and consistent homogeneous cooling process. Thanks to this technology, the self-regulating matrix achieves the same resistance and the same power over the entire length.
As a result of post-treatment with radiation crosslinking, the self-regulating matrix achieves thermal stability and gains greater resistance to cyclic loads, which allows the cable to maintain its heating power over its entire lifetime.
FEATURES
APPLICATION
When using the machine with the C feature, the maximum length of the sections
Medicine |
Shutdown temperature , ° C |
230 V |
|
|
|
|
|
16A |
20A |
25A |
32A |
TSL-10P (F) |
10 -15 -30 |
205 139 120 |
205 186 150 |
205 190 170 |
205 195 195 |
TSL-15P (F) |
10 -15 -30 |
145 93 77 |
162 125 106 |
162 142 135 |
162 160 160 |
TSL-25P (F) |
10 -15 -30 |
88 58 45 |
117 75 64 |
120 95 82 |
126 117 100 |
TSL-33P (F) |
10 -15 -30 |
70 49 43 |
70 49 43 |
98 80 65 |
108 95 82 |
Self-regulating heating cable in roof and industrial systems
A significant layer of snow on roofs can cause destruction of the roof, gutters, pipelines, tanks and other equipment. This problem applies to residential areas, private houses, industrial enterprises, warehouse hangars, oil refineries, chemical enterprises. A modern solution can be a heating cable. It is recommended to lay technical facilities for the transfer of gas and oil during the assembly and installation of the roof, so most modern buildings and structures are simply impossible to do without such a system. A self-regulating heating cable with properly installed and correctly calculated power can completely solve the problem of ice formation on the roof, stagnation in pipelines, providing stable operation at subzero temperatures.
The functionality of the equipment from the company “Thermal Systems”
The company has been offering its products to the market for years. The quality of this product is high, its technical characteristics are not inferior to foreign counterparts. The manufacturer offers relevant solutions and reliable designs that fully meet today’s requirements.
With solid manufacturing facilities, the company helps to effectively cooperate with large enterprises, construction concerns and industrial transportation systems.
Own production technology takes into account the climatic features of the regions, a wide range of nomenclature allows you to fully solve functional problems. Equipment varies in power, resistance to environmental influences, robustness against aggressive substances.
Price advantages of heating cable
The company “Thermal Systems” uses 90% domestic resources, this allows us to offer the most affordable prices for self-regulating heating cable in the industry. Own technology and proven logistics help optimize domestic costs and offer a competitive price in the market.
A wide variety of models, existing engineering solutions allow the installation of integrated systems. In addition to heating cables, the company produces fasteners, switching elements, recording and control equipment. Experts are ready to offer not only a high quality product, but a complete anti-icing system design with subsequent installation and commissioning. The company maintains modules that have already been implemented.
Uploaded